Home / Guides / Boiler not working after a power cut

Guide: fault finding 17 November 2026 · 5 minute read

Boiler Not Working After a Power Cut? What to Check

Most boilers start again on their own when the power comes back. If yours hasn’t, it’s usually something simple: a tripped switch, a clock that’s lost its time, a thermostat that needs to reconnect, or a lockout that needs one reset.

  • 105to report a power cut, free
  • 15minutes a Worcester CDi runs at low output after the power returns
  • 1reset, then call us if it locks out again
Heat Network engineer showing a customer where the boiler reset is 4checks in order

A gas boiler needs electricity to run its fan, pump and controls, so when the power goes off, the heating and hot water go with it. SP Energy Networks, who run the electricity network in Fife, say many heating systems won’t work in a power cut.

When the power comes back, most boilers start up again by themselves. If yours hasn’t, work through the checks below in order. None of them involve opening the boiler.

Introduction01

While the power is off

SP Energy Networks’ advice.

  • If neighbours have power and you don’t, check the trip switch at your fuse box
  • Call 105 to report a power cut or get updates. It’s free, whoever supplies your electricity
  • Unplug sensitive electronics, and switch off heaters, cookers and irons so they don’t come on unexpectedly
  • Leave one light switched on so you know when the power is back
  • When it returns, switch things back on one at a time

Portable heaters can help in the meantime, but take care where you put them. If you use a gas or paraffin heater, keep the room ventilated and make sure your carbon monoxide alarm works.

Heat Network engineer arriving at a stone-built home in Fife Out across Fife
i

Smell gas?

Don’t smoke, use a naked flame or touch any switches. Open doors and windows, turn the gas off at the meter if it’s safe to reach, go outside and call the National Gas Emergency Service on 0800 111 999.

Power off02

When the power comes back

Check these in order.

The fuse box

If the boiler is completely dead, with no lights or display, look at your consumer unit. A switch may have tripped. Turn it back on once. If it trips again straight away, leave it off and call an electrician.

The boiler’s switch

Most boilers are wired through a fused switch on the wall nearby, often called the fused spur. Some have a plug instead. Make sure it’s on. If it is, the rest of the house has power and the boiler is still dead, the fuse may have gone. That’s one for an engineer or electrician.

The clock and thermostat

Some timers lose their time or go back to default settings after a power cut. Set the clock and check the heating times. Smart thermostats usually reconnect by themselves, but can take a few minutes.

Pressure, then one reset

Check the gauge reads about 1 to 1.5 bar with the boiler cold, and top up if it’s low. If there’s a fault showing, reset once. On a Worcester Greenstar CDi Classic, if the on/off light doesn’t come back after a short power cut, Worcester says to switch the boiler off at its supply, wait a few seconds and switch it on again.

i

Give it a few minutes

Some boilers run a start-up routine after the power has been off. Worcester’s Greenstar CDi runs at low output for 15 minutes to refill its condensate trap, every time the supply has been interrupted.

Power back03

Smart thermostats and timers

Often the boiler is fine and the controls aren’t.

If the boiler’s display is on but the heating won’t come on, it’s usually the controls. Ideal notes that a timer can reset to its default settings after a power loss, and Viessmann lists the power supply and failing backup batteries among the things that upset timers.

Hive, tado and other smart controls

Worcester says its EasyControl remembers its settings in a power cut and picks the time up from the internet when the power returns. Your broadband router needs to restart too, so give everything a few minutes.

If a Hive thermostat still shows offline, Hive’s advice is to restart the hub at the wall socket and give it 5 to 10 minutes. The receiver’s status and heating lights should go green. If it still won’t connect, follow the maker’s steps in the app. Our Hive or tado guide covers how they work.

Engineer checking a boiler's settings and controls Controls
Controls04

When it’s a fault

And why more resets won’t help.

It keeps locking out

One reset is fine. If the boiler locks out again, stop. More resets won’t fix a fault, and some boilers stop taking them. A Worcester Greenstar 4000 can go into what Worcester calls super lock-out if five lockouts are reset within 15 minutes, and then it needs an engineer. An Ideal Logic+ shows Too many resets after five resets in 15 minutes.

It’s still dead with power at the switch

Then the cause is inside the boiler. Worcester’s manual lists the wiring and the fuse inside the casing as the engineer’s checks for a boiler with a dark display. It can also be the main control board, the PCB. Any of these needs a Gas Safe registered engineer to diagnose.

It runs, but not properly

If the boiler fires but cuts out, or the heating or hot water isn’t right, our boiler keeps cutting out guide goes through the usual causes.

Heat Network engineer checking a wall-hung boiler in a Fife kitchen Diagnosis
i

Never take the casing off

There’s mains electricity and gas inside a boiler. Only a Gas Safe registered engineer should remove the cover.

Faults05

What you see and what it usually means

 Likely causeWhat to do
Boiler dead, and the rest of the housePower still off, or a tripped switchCheck the fuse box, call 105
Boiler dead, house has powerThe boiler’s switch, or a fuseCheck the switch, then call us
Boiler on, heating won’t come onClock, timer or thermostatSet the time, check the controls
Smart thermostat offlineHub or receiver reconnectingRestart the hub, wait 10 minutes
Fault code or lockout lightLockout after the restartReset once
Gauge below 1 barLow pressureTop up with the filling loop
Locks out again, or stays deadA fault inside the boilerAn engineer
Symptoms06

What should I do next?

  • Power’s still offCall 105

    Free, whoever your supplier is.

  • Clock or thermostat was outYou’re sorted

    No visit needed.

  • Pressure below 1 barTop it up

    Our guide shows how.

  • Still dead, or locks out againBook a repair visit

    £120 including VAT, before any parts.

What should I do next?07

Common questions

Will my boiler work in a power cut?

No. A gas boiler needs electricity for its fan, pump and controls, so the heating and hot water stop until the power returns.

How do I reset my boiler after a power cut?

Make sure it has power first: the fuse box, then the boiler’s switch. Then reset it once using the button or the method in your manual. On a Worcester Greenstar CDi Classic, if the on/off light doesn’t come back after a short power cut, Worcester says to switch the boiler off at its supply, wait a few seconds and switch it back on. If it locks out again, stop and call an engineer.

Why has my heating timer lost its settings?

Some timers and programmers lose the time or go back to default settings when the power goes off. Set the clock and check your on and off times. Smart thermostats usually pick up the time from the internet.

My smart thermostat isn’t working after a power cut. What do I do?

Give it a few minutes, as the router, hub and thermostat all need to reconnect. Hive’s advice is to restart the hub at the wall socket and wait 5 to 10 minutes. If it still shows offline, follow the maker’s reconnection steps in the app.

Can a power cut damage a boiler?

Usually the boiler just needs restarting. If it stays dead with power at its switch, or keeps locking out, there’s a fault inside, such as a fuse or the control board, and it needs a Gas Safe registered engineer.

Is it covered by Home Care?

Boiler repairs are included on the Home Care Boiler and Complete plans, with parts and labour. Controls such as thermostats are included on Home Care System and Complete. Faults that were there before you joined aren’t covered.

Common questions08
Philip Jones, founder of The Heat Network

Reviewed by

Philip Jones

Founder of The Heat Network and a Gas Safe registered engineer (626544). Philip started the business in Dunfermline in 2018 and works on boilers and heating systems across Fife every week. He holds Gas Safe, F-Gas, BPEC Level 3 Heat Pump Systems, unvented and water regulations qualifications, and the business is a Worcester Bosch Accredited installer.

Last reviewed 17 November 2026. More about Philip

Not sure what you need? Give us a shout.

Book online in a couple of minutes or give the office a call, Mon to Fri, 9am to 5pm. We’ll tell you what we think, and if the answer is to leave things as they are, we’ll say that too.

i

Worcester Bosch Accredited Installer

Guarantees of up to 12 years on the boilers we fit. Gas Safe registered. Fife Trusted Trader. 400+ customer reviews.