Worcester Bosch EA fault code: what it means and what to do

EA means the boiler tried to light and couldn’t detect a flame, so it locked itself out. Newer Greenstar boilers show it as 227. Often it’s the gas supply or a frozen condensate pipe, and you can often sort it yourself.

  • EAon older Greenstar boilers
  • 227the same fault on the 2000, 4000 and 8000
  • 1 to 1.5bar, the pressure to look for when cold
Worcester Bosch Greenstar 4000 combi boiler Greenstar 4000

You’ve gone to turn the heating on, nothing’s happening, and the boiler is flashing EA, or 227 if it’s one of the newer ones. It’s one of the most common Worcester Bosch codes we see, and it’s worth a couple of minutes’ checking before you book anyone.

It means the boiler tried to light the burner and didn’t detect a flame, so it shut itself down to stay safe. Worcester calls it flame not detected, or ignition lockout. It needs a manual reset to clear.

Introduction01

What causes it

Some you can check. Some need an engineer.

Things you can check

  • No gas getting to the boiler
  • No credit on a prepayment meter
  • The gas valve under the boiler turned off
  • A frozen or blocked condensate pipe

Things for an engineer

  • The ignition or flame sensing electrodes
  • A blocked or damaged flue
  • Low gas pressure to the boiler
  • A fault with the gas valve or control board

If you hear gurgling from the boiler in cold weather, it’s very likely the condensate pipe. Worcester itself says that’s usually safe to thaw yourself. Our frozen condensate pipe guide shows you how.

Worcester Bosch Greenstar 4000 fitted in a cupboard by The Heat Network One we fitted
What causes it02

What to try first

In this order.

Check your gas

Does the hob light? If nothing on gas works, check the meter: credit on a prepayment meter, and the handle on the gas valve in line with the pipe. If it’s a supply problem, contact your gas supplier.

Check the boiler’s gas valve

There’s usually a valve on the gas pipe under the boiler. Make sure it hasn’t been knocked off.

Check the condensate pipe

In a frost, look at the white plastic pipe outside. If it’s frozen and at ground level, thaw it with warm water, never boiling. Don’t try to reach one that’s up high.

Reset once

Use the reset for your model (see the table below). Give it two or three minutes to restart. If it locks out again, try one more time after any fix. If EA comes back, stop and call us.

i

Our advice on resets

Worcester doesn’t publish a limit. We’d say one reset, and one more after you’ve fixed something like a frozen pipe. If it keeps locking out, something needs looking at, and more resets won’t fix it.

What to try first03

How to reset your Greenstar

 What you’ll seeHow to reset
Greenstar CDi ClassicEAPress and hold the reset button for 2 seconds
Greenstar Ri (older, with knobs)Flashing lightTurn the heating knob to RESET, hold for about 5 seconds, then turn it back
Greenstar iEA on the displayPress the reset button
Greenstar 2000H symbol and a numberPress the arrow buttons together until the symbols go, or switch it off and on
Greenstar 4000 and 8000227 and a symbolPress the up and down arrows together until Reset shows

From Worcester Bosch user and installation manuals, checked 2 November 2026. Your manual has the exact steps for your boiler.

Resetting04

What should I do next?

What should I do next?05

Common questions

What does EA mean on a Worcester boiler?

Flame not detected, or ignition lockout. The boiler tried to light and couldn’t sense a flame, so it shut itself down. It needs a manual reset to clear.

What is fault 227 on a Worcester Greenstar?

On the Greenstar 2000, 4000 and 8000, 227 means no flame signal after ignition. It’s the same fault older Worcester boilers show as EA.

Is 1017 the same as EA?

No. 1017 means the water pressure is too low. Top it up to between 1 and 1.5 bar with the boiler cold, then reset. If you’re topping up more than once or twice a year, something’s wrong, often a leak.

How many times should I reset my Worcester boiler?

Worcester doesn’t give a number. Our advice is one reset, and one more after fixing something like a frozen condensate pipe. If EA keeps coming back, book a repair rather than keep resetting.

Can a frozen condensate pipe cause EA?

Yes. Worcester lists a frozen or blocked condensate pipe as a cause. You’ll often hear gurgling too. Thaw it with warm water if it’s at ground level, then reset.

My boiler is still under its Worcester guarantee. Who do I call?

Us, or Worcester Bosch. We’re a Worcester Bosch Accredited Installer. If we fitted it, call us first. Repairs under guarantee depend on the boiler having been serviced every year.

Common questions06

Not sure what you need? Give us a shout.

Book online in a couple of minutes or give the office a call, Mon to Fri, 9am to 5pm. We’ll tell you what we think, and if the answer is to leave things as they are, we’ll say that too.

i

Worcester Bosch Accredited Installer

Guarantees of up to 12 years on the boilers we fit. Gas Safe registered. Fife Trusted Trader. 400+ customer reviews.