title: "Combi boiler with no hot water but the heating works?"
url: https://theheatnetwork.co.uk/guides/combi-boiler-no-hot-water-heating-works/
description: "Combi giving heating but no hot water? The checks you can do safely, from the temperature dial to your mains supply, and faults like the diverter valve."
updated: 2026-11-21
---

# Combi boiler with no hot water but the heating works?

You turn on the hot tap and it stays cold, but the radiators are warming up nicely. On a combi boiler, that’s a useful clue.

A combi heats the radiators and the hot water with the same burner. If the heating works, the boiler is getting gas, it’s lighting, and the pressure is probably fine. So the problem is on the hot water side. Some causes you can check in a few minutes. Others are parts inside the boiler that need a Gas Safe registered engineer.

Introduction 01

Reviewed by [Philip Jones](https://theheatnetwork.co.uk/about-us-profile/), Gas Safe registered engineer (626544) and founder of The Heat Network. Updated 24 November 2026.

## How a combi makes hot water

Three parts do the work.

When you open a hot tap, mains water starts flowing through the boiler. A small sensor, the flow sensor or flow turbine, picks that up and tells the boiler to fire. The diverter valve then switches the heat away from the radiators and into the plate heat exchanger, which heats the tap water as it passes through.

If the sensor doesn’t register, the diverter valve sticks, or the plate heat exchanger is scaled up, you can get warm radiators and cold or lukewarm taps.

Before any of that, there are a few simple things to rule out.

How it works 02

## Check these first

None of them involve opening the boiler.

### The hot water setting

Make sure the hot water hasn’t been switched off or turned right down. On Worcester’s Greenstar CDi Classic, the dial runs from about 40°C to 60°C. Ideal notes that below 30°C the water will feel cold.

### Run the tap properly

A combi only fires for hot water once enough is flowing. Ideal’s Logic+ combi works down to 2 litres a minute. Open the hot tap well rather than a trickle, and try another tap to see if it’s one tap or all of them.

### Your cold water supply

Check the cold taps run normally. If they’re weak or off too, it’s the supply, not the boiler. Ideal suggests checking the valve on the cold pipe under the boiler hasn’t been turned off. If no taps run at all, check the stop valve under the kitchen sink is fully open. If it is, check Scottish Water’s website for problems in your area, or call them.

### A fault code

If the display shows a code, look it up in your manual or on our [fault codes page](https://theheatnetwork.co.uk/boiler-fault-codes/). Reset once. If it comes back, stop and book a repair.

### Mains pressure in Scotland

Scottish Water aims to give at least 1.0 bar where the supply enters your property, but can’t guarantee it. A combi heats water straight from the mains, so it can only do as much as the supply allows.

Your checks 03

## If the heating’s playing up too

Then it’s probably not the hot water side.

### A frozen or blocked condensate pipe

A frozen condensate pipe usually stops the boiler altogether, so you lose the heating and the hot water. If the boiler is also going off, gurgling or showing a fault in cold weather, check the plastic pipe outside first. Our [frozen condensate pipe guide](https://theheatnetwork.co.uk/guides/frozen-condensate-pipe/) shows how to thaw it with warm water, never boiling.

### Low pressure

Most boilers shut down when the pressure drops too low, which stops both. With the boiler cold, the gauge should read about 1 to 1.5 bar. Our [boiler pressure guide](https://theheatnetwork.co.uk/guides/boiler-pressure-guide/) shows how to top it up through the filling loop.

### Smell gas?

Don’t smoke, use a naked flame or touch any switches. Open doors and windows, turn the gas off at the meter if it’s safe to reach, go outside and call the National Gas Emergency Service on 0800 111 999.

Both off 04

## Faults for an engineer

Inside the casing, so not a DIY job.

### The diverter valve

The usual suspect when the heating works and the hot water doesn’t. If it sticks in the heating position, you get warm radiators and cold taps. Ideal suggests turning a hot tap on and off a few times with the heating on, which can free a sticking valve. If that doesn’t work, Vaillant, Baxi and Viessmann all say it needs an engineer, and as it means opening the boiler, that has to be a Gas Safe registered engineer.

### The flow sensor

If it’s blocked or faulty, the boiler doesn’t know you’ve opened a tap, so it never switches over. Worcester’s manual lists checking the flow turbine when a combi isn’t reaching its hot water temperature.

### Scale in the plate heat exchanger

Limescale can build up in the part that heats the tap water and leave it lukewarm. Most of Scotland’s water is soft, so we see it less here than in hard water areas, but Worcester still lists the plate heat exchanger as a check.

[Book a repair](https://theheatnetwork.co.uk/book/?service=repair) [About boiler repairs](https://theheatnetwork.co.uk/boiler-repair-fife/)

### Leave the casing on

Everything in this section is inside the boiler. Only a Gas Safe registered engineer should take the cover off.

Engineer jobs 05

## Symptom, likely cause and who fixes it

| | Likely cause | Who fixes it |
| --- | --- | --- |
| Taps cold, radiators hot | Diverter valve or flow sensor | An engineer |
| Hot at full flow, cold at a trickle | Too little flow to fire the boiler | Open the tap further |
| Hot at a gentle flow, cooler at full | More water than the boiler can heat | Turn the tap down a little |
| Never more than lukewarm | Temperature setting, or scale | Check the dial, then an engineer |
| Cold taps weak too | Your water supply | Check the valves, or Scottish Water |
| Both off, gurgling in a frost | Frozen condensate pipe | You, if it’s at ground level |
| Both off, gauge below 1 bar | Low pressure | You, with the filling loop |

Symptoms 06

## What should I do next?

- A setting was off [You’re sorted](https://theheatnetwork.co.uk/guides/) No visit needed.
- Both off in a frost [Thaw the pipe](https://theheatnetwork.co.uk/guides/frozen-condensate-pipe/) Warm water, then reset.
- Taps still cold after the checks [Book a repair visit](https://theheatnetwork.co.uk/book/?service=repair) £120 including VAT, before any parts.
- You’re on Home Care Boiler or Complete [Boiler repairs are included](https://theheatnetwork.co.uk/boiler-cover/) Parts and labour, Monday to Friday. Call us and tell us you’re a member.

What should I do next? 07

## Common questions

**Why do I have heating but no hot water on my combi?**

If the settings are right and your cold supply is fine, the usual cause is the diverter valve sticking in the heating position. A faulty flow sensor can do the same. Both are inside the boiler and need a Gas Safe registered engineer.

**Can I fix a diverter valve myself?**

No, it’s inside the boiler casing. Ideal suggests turning a hot tap on and off a few times with the heating on, which can free a sticking valve. If that doesn’t work, it needs an engineer.

**Why is my hot water only lukewarm?**

Check the hot water setting first. If you’re running the tap very hard, the boiler may not be able to heat that much water, so try it a little lower. If it’s still lukewarm, scale or a fault in the boiler may be the cause.

**Can low mains pressure stop my combi giving hot water?**

Yes. A combi heats water straight from the mains, and if too little is flowing it may not fire for hot water at all. Scottish Water aims for at least 1.0 bar where the supply enters your property, but can’t guarantee it.

**Is it safe to keep using the heating?**

Yes, if the boiler is running normally with no fault showing. If you ever smell gas, call 0800 111 999 from outside.

**Is it covered by Home Care?**

Breakdown repairs to the boiler, such as a diverter valve or flow sensor, are included on the Home Care Boiler and Complete plans, with parts and labour. Faults that were there before you joined, and damage caused by sludge, aren’t covered.

Common questions 08

## Related pages

[Boiler repairs](https://theheatnetwork.co.uk/boiler-repair-fife/) [No hot water? Common causes](https://theheatnetwork.co.uk/guides/no-hot-water-boiler-troubleshooting/) [Frozen condensate pipe](https://theheatnetwork.co.uk/guides/frozen-condensate-pipe/) [Home Care plans](https://theheatnetwork.co.uk/boiler-cover/)

Sources: [Vaillant, no hot water: what to check](https://www.vaillant.co.uk/advice/heating-tips/home-advice/no-hot-water-what-to-check/); [Baxi, what to check if you have no hot water](https://www.baxi.co.uk/help-and-advice/faqs/what-to-check-if-you-have-no-hot-water); [Ideal, no hot water: here’s what to do](https://idealheating.com/tips-and-advice/no-hot-water-heres-what-to-do); [Ideal, why can’t I get hot water?](https://idealheating.com/support/faqs/boilers/why-cant-i-get-hot-water); [Viessmann, my boiler is working but I have no hot water](https://www.viessmann.co.uk/heating-advice/my-boiler-is-working-but-i-have-no-hot-water); [Worcester Bosch, Greenstar CDi Classic combi user instructions](https://worcester-bosch.co.uk/support/literature/download/6720815728); [Worcester Bosch, Greenstar 4000 installation manual](https://worcester-bosch.co.uk/support/literature/download/6720891161); [Ideal, Logic+ Combi installation and servicing manual](https://www.heatingspareparts.com/content/docs/ideal_47-348-65_logic%20plus%20combi%20user%20installation%20instructions.pdf); [Scottish Water, your water pressure explained](https://appgateway-west.scottishwater.co.uk/-/media/ScottishWater/Document-Hub/Factsheets-and-Leaflets/Factsheets/090821SWYourWaterPressureExplained2021v1pageslr.pdf); [Drinking Water Quality Regulator for Scotland, water hardness](https://dwqr.scot/public-water-supply/drinking-water-quality-faqs/water-hardness/). Checked 3 November 2026.

Share this page WhatsApp Facebook LinkedIn Email

Related pages 09

Reviewed by

[Philip Jones](https://theheatnetwork.co.uk/about-us-profile/)

Founder of The Heat Network and a Gas Safe registered engineer (626544). Philip started the business in Dunfermline in 2018 and works on boilers and heating systems across Fife every week. He holds Gas Safe, F-Gas, BPEC Level 3 Heat Pump Systems, unvented and water regulations qualifications, and the business is a Worcester Bosch Accredited installer.

Last reviewed 24 November 2026. [More about Philip](https://theheatnetwork.co.uk/about-us-profile/)

## Not sure what you need? Give us a shout.

Book online in a couple of minutes or give the office a call, Mon to Fri, 9am to 5pm. We’ll tell you what we think, and if the answer is to leave things as they are, we’ll say that too.

[Book online](https://theheatnetwork.co.uk/book/) [Call 01383 660098](tel:01383660098) [Get a boiler quote](https://portal.theheatnetwork.co.uk/quote)

### Worcester Bosch Accredited Installer

Guarantees of up to 12 years on the boilers we fit. Gas Safe registered. Fife Trusted Trader. 400+ customer reviews.

---

The Heat Network Ltd, Dunfermline, Fife. Phone 01383 660098. Email hello@theheatnetwork.co.uk. Gas Safe registered 626544. Company number SC624367.

This is a plain text copy of https://theheatnetwork.co.uk/guides/combi-boiler-no-hot-water-heating-works/ for AI tools. Site guide: https://theheatnetwork.co.uk/llms.txt