title: "Boiler not working after a power cut? What to check"
url: https://theheatnetwork.co.uk/guides/boiler-not-working-after-power-cut/
description: "Power back but the boiler isn't? Check the fuse box, the boiler's switch, the clock, your smart thermostat and the pressure, then reset once. When to call us."
updated: 2026-11-21
---

# Boiler not working after a power cut? What to check

A gas boiler needs electricity to run its fan, pump and controls, so when the power goes off, the heating and hot water go with it. SP Energy Networks, who run the electricity network in Fife, say many heating systems won’t work in a power cut.

When the power comes back, most boilers start up again by themselves. If yours hasn’t, work through the checks below in order. None of them involve opening the boiler.

Introduction 01

Reviewed by [Philip Jones](https://theheatnetwork.co.uk/about-us-profile/), Gas Safe registered engineer (626544) and founder of The Heat Network. Updated 17 November 2026.

## While the power is off

SP Energy Networks’ advice.

- If neighbours have power and you don’t, check the trip switch at your fuse box
- Call 105 to report a power cut or get updates. It’s free, whoever supplies your electricity
- Unplug sensitive electronics, and switch off heaters, cookers and irons so they don’t come on unexpectedly
- Leave one light switched on so you know when the power is back
- When it returns, switch things back on one at a time

Portable heaters can help in the meantime, but take care where you put them. If you use a gas or paraffin heater, keep the room ventilated and make sure your carbon monoxide alarm works.

### Smell gas?

Don’t smoke, use a naked flame or touch any switches. Open doors and windows, turn the gas off at the meter if it’s safe to reach, go outside and call the National Gas Emergency Service on 0800 111 999.

Power off 02

## When the power comes back

Check these in order.

### The fuse box

If the boiler is completely dead, with no lights or display, look at your consumer unit. A switch may have tripped. Turn it back on once. If it trips again straight away, leave it off and call an electrician.

### The boiler’s switch

Most boilers are wired through a fused switch on the wall nearby, often called the fused spur. Some have a plug instead. Make sure it’s on. If it is, the rest of the house has power and the boiler is still dead, the fuse may have gone. That’s one for an engineer or electrician.

### The clock and thermostat

Some timers lose their time or go back to default settings after a power cut. Set the clock and check the heating times. Smart thermostats usually reconnect by themselves, but can take a few minutes.

### Pressure, then one reset

Check the gauge reads about 1 to 1.5 bar with the boiler cold, and top up if it’s low. If there’s a fault showing, reset once. On a Worcester Greenstar CDi Classic, if the on/off light doesn’t come back after a short power cut, Worcester says to switch the boiler off at its supply, wait a few seconds and switch it on again.

### Give it a few minutes

Some boilers run a start-up routine after the power has been off. Worcester’s Greenstar CDi runs at low output for 15 minutes to refill its condensate trap, every time the supply has been interrupted.

Power back 03

## Smart thermostats and timers

Often the boiler is fine and the controls aren’t.

If the boiler’s display is on but the heating won’t come on, it’s usually the controls. Ideal notes that a timer can reset to its default settings after a power loss, and Viessmann lists the power supply and failing backup batteries among the things that upset timers.

### Hive, tado and other smart controls

Worcester says its EasyControl remembers its settings in a power cut and picks the time up from the internet when the power returns. Your broadband router needs to restart too, so give everything a few minutes.

If a Hive thermostat still shows offline, Hive’s advice is to restart the hub at the wall socket and give it 5 to 10 minutes. The receiver’s status and heating lights should go green. If it still won’t connect, follow the maker’s steps in the app. Our [Hive or tado guide](https://theheatnetwork.co.uk/guides/hive-or-tado/) covers how they work.

Controls 04

## When it’s a fault

And why more resets won’t help.

### It keeps locking out

One reset is fine. If the boiler locks out again, stop. More resets won’t fix a fault, and some boilers stop taking them. A Worcester Greenstar 4000 can go into what Worcester calls super lock-out if five lockouts are reset within 15 minutes, and then it needs an engineer. An Ideal Logic+ shows Too many resets after five resets in 15 minutes.

### It’s still dead with power at the switch

Then the cause is inside the boiler. Worcester’s manual lists the wiring and the fuse inside the casing as the engineer’s checks for a boiler with a dark display. It can also be the main control board, the PCB. Any of these needs a Gas Safe registered engineer to diagnose.

### It runs, but not properly

If the boiler fires but cuts out, or the heating or hot water isn’t right, our [boiler keeps cutting out guide](https://theheatnetwork.co.uk/guides/boiler-keeps-cutting-out/) goes through the usual causes.

[Book a repair](https://theheatnetwork.co.uk/book/?service=repair) [About boiler repairs](https://theheatnetwork.co.uk/boiler-repair-fife/)

### Never take the casing off

There’s mains electricity and gas inside a boiler. Only a Gas Safe registered engineer should remove the cover.

Faults 05

## What you see and what it usually means

| | Likely cause | What to do |
| --- | --- | --- |
| Boiler dead, and the rest of the house | Power still off, or a tripped switch | Check the fuse box, call 105 |
| Boiler dead, house has power | The boiler’s switch, or a fuse | Check the switch, then call us |
| Boiler on, heating won’t come on | Clock, timer or thermostat | Set the time, check the controls |
| Smart thermostat offline | Hub or receiver reconnecting | Restart the hub, wait 10 minutes |
| Fault code or lockout light | Lockout after the restart | Reset once |
| Gauge below 1 bar | Low pressure | Top up with the filling loop |
| Locks out again, or stays dead | A fault inside the boiler | An engineer |

Symptoms 06

## What should I do next?

- Power’s still off [Call 105](tel:105) Free, whoever your supplier is.
- Clock or thermostat was out [You’re sorted](https://theheatnetwork.co.uk/guides/) No visit needed.
- Pressure below 1 bar [Top it up](https://theheatnetwork.co.uk/guides/boiler-pressure-guide/) Our guide shows how.
- Still dead, or locks out again [Book a repair visit](https://theheatnetwork.co.uk/book/?service=repair) £120 including VAT, before any parts.

What should I do next? 07

## Common questions

**Will my boiler work in a power cut?**

No. A gas boiler needs electricity for its fan, pump and controls, so the heating and hot water stop until the power returns.

**How do I reset my boiler after a power cut?**

Make sure it has power first: the fuse box, then the boiler’s switch. Then reset it once using the button or the method in your manual. On a Worcester Greenstar CDi Classic, if the on/off light doesn’t come back after a short power cut, Worcester says to switch the boiler off at its supply, wait a few seconds and switch it back on. If it locks out again, stop and call an engineer.

**Why has my heating timer lost its settings?**

Some timers and programmers lose the time or go back to default settings when the power goes off. Set the clock and check your on and off times. Smart thermostats usually pick up the time from the internet.

**My smart thermostat isn’t working after a power cut. What do I do?**

Give it a few minutes, as the router, hub and thermostat all need to reconnect. Hive’s advice is to restart the hub at the wall socket and wait 5 to 10 minutes. If it still shows offline, follow the maker’s reconnection steps in the app.

**Can a power cut damage a boiler?**

Usually the boiler just needs restarting. If it stays dead with power at its switch, or keeps locking out, there’s a fault inside, such as a fuse or the control board, and it needs a Gas Safe registered engineer.

**Is it covered by Home Care?**

Boiler repairs are included on the Home Care Boiler and Complete plans, with parts and labour. Controls such as thermostats are included on Home Care System and Complete. Faults that were there before you joined aren’t covered.

Common questions 08

## Related pages

[Boiler repairs](https://theheatnetwork.co.uk/boiler-repair-fife/) [Boiler fault codes](https://theheatnetwork.co.uk/boiler-fault-codes/) [Why does my boiler keep turning off?](https://theheatnetwork.co.uk/guides/boiler-keeps-cutting-out/) [Home Care plans](https://theheatnetwork.co.uk/boiler-cover/)

Sources: [SP Energy Networks, what to do in a power cut](https://spenergynetworks.co.uk/pages/what_to_do_in_a_power_cut.asp); [Worcester Bosch, power cuts and EasyControl](https://www.worcester-bosch.co.uk/support/troubleshooting/faqs/controls-faqs/weve-had-a-power-cut-does-that-affect-easycontrol); [Worcester Bosch, Greenstar CDi Classic combi user instructions](https://worcester-bosch.co.uk/support/literature/download/6720815728); [Worcester Bosch, Greenstar 4000 installation manual](https://worcester-bosch.co.uk/support/literature/download/6720891161); [Ideal, no hot water: here’s what to do](https://idealheating.com/tips-and-advice/no-hot-water-heres-what-to-do); [Ideal, Logic+ Combi installation and servicing manual](https://www.heatingspareparts.com/content/docs/ideal_47-348-65_logic%20plus%20combi%20user%20installation%20instructions.pdf); [Viessmann, my boiler is working but I have no hot water](https://www.viessmann.co.uk/heating-advice/my-boiler-is-working-but-i-have-no-hot-water); [Hive, what to do if your thermostat is offline](https://www.hivehome.com/ie/support/Help_Using_Hive/HUH_Hive_Active_Heating_Thermostat/What-to-do-if-your-Hive-Thermostat-is-offline); [Gas Safe Register, what to do in a gas emergency](https://www.gassaferegister.co.uk/gas-emergency/what-to-do-in-a-gas-emergency/). Checked 3 November 2026.

Share this page WhatsApp Facebook LinkedIn Email

Related pages 09

Reviewed by

[Philip Jones](https://theheatnetwork.co.uk/about-us-profile/)

Founder of The Heat Network and a Gas Safe registered engineer (626544). Philip started the business in Dunfermline in 2018 and works on boilers and heating systems across Fife every week. He holds Gas Safe, F-Gas, BPEC Level 3 Heat Pump Systems, unvented and water regulations qualifications, and the business is a Worcester Bosch Accredited installer.

Last reviewed 17 November 2026. [More about Philip](https://theheatnetwork.co.uk/about-us-profile/)

## Not sure what you need? Give us a shout.

Book online in a couple of minutes or give the office a call, Mon to Fri, 9am to 5pm. We’ll tell you what we think, and if the answer is to leave things as they are, we’ll say that too.

[Book online](https://theheatnetwork.co.uk/book/) [Call 01383 660098](tel:01383660098) [Get a boiler quote](https://portal.theheatnetwork.co.uk/quote)

### Worcester Bosch Accredited Installer

Guarantees of up to 12 years on the boilers we fit. Gas Safe registered. Fife Trusted Trader. 400+ customer reviews.

---

The Heat Network Ltd, Dunfermline, Fife. Phone 01383 660098. Email hello@theheatnetwork.co.uk. Gas Safe registered 626544. Company number SC624367.

This is a plain text copy of https://theheatnetwork.co.uk/guides/boiler-not-working-after-power-cut/ for AI tools. Site guide: https://theheatnetwork.co.uk/llms.txt